ADSS — All-Dielectric Self-Supporting Optical Cable

A lightweight, non-metallic fiber optic cable engineered for reliable aerial deployment without the need for a messenger wire.

ADSS optical cable adopts a loose-tube stranded structure, in which 250 μm optical fibers are inserted into loose tubes made of high-modulus materials, and the loose tubes are filled with water-blocking compounds. The loose tubes (together with filling ropes) are stranded around a non-metallic central strength member (FRP) to form a compact cable core, and the gaps in the cable core are filled with water-blocking ointment. A polyethylene (PE) inner sheath is extruded over the cable core, then aramid fibers for reinforcement are stranded, and finally a polyethylene (PE) outer sheath or an anti-tracking (AT) outer sheath is extruded.

Key features

  1. Can be installed without power interruption
  2. Adopts AT sheath with excellent anti-tracking performance
  3. Light weight and small cable diameter, which reduces the impact of ice and wind, as well as the load on towers and supports
  4. Large span, with the maximum span exceeding 1000 meters
  5. Possesses excellent tensile properties and temperature characteristics
  6. Expected service life is more than 30 years

Construction

Loose tube250 μm optical fibers in high-modulus loose tubes, filled with water-blocking compound.Central strength memberNon-metallic FRP rod — the loose tubes strand around it to form a compact, fully dielectric core.Inner sheathPolyethylene (PE), extruded over the cable core.ReinforcementAramid yarn, stranded over the inner sheath for tensile strength.Outer sheathPolyethylene (PE) or anti-tracking (AT) sheath.

Optical Fiber Specification

Fiber typeG652D — full color coding to national standard.Mode field diameter9.2 ± 0.4 μmAttenuation (fiber matching)≤0.345 dB/km (1310nm) · ≤0.205 dB/km (1550nm)Attenuation (factory outlet)≤0.350 dB/km (1310nm) · ≤0.210 dB/km (1550nm)Cut-off wavelength (CCW)≤1260nmTemperature characteristic (TC)≤0.05 (−40°C to +70°C)

Typical applications

ScenariosTransmission lines, distribution networks, renewable energy projects, and utility communication systems.

Structural Parameters

Ref. Outer Diameter (mm)Ref. Weight — PE Sheath (kg/km)Ref. Weight — AT Sheath (kg/km)Rec. Daily Max. Working Tension (kN)Max. Allowable Working Tension (kN)Break Strength (kN)Strength Member CSA (mm²)Modulus of Elasticity (kN/mm²)Heat Expansion Coefficient (×10⁻⁶/K)Suitable Span A (m)Suitable Span B (m)Suitable Span C (m)Suitable Span D (m)
12.51251361.54104.67.61.8160100140100
13.01321422.256157.68.31.5230150200150
13.31371483.082010.359.451.3300200290200
13.61451563.6102413.810.81.2370250350250
13.81471594.5123014.311.81.0420280400280
14.51641775.4153618.413.60.9480320460320
14.91711856.75184522.016.40.6570380550380
15.11791937.95225326.418.00.3670460650460
15.51902049.0266032.219.10.1750530750510
15.619420810.5287033.019.60.1800560800560
16.321122612.75348540.020.10.1880650880650
16.822624215.454110348.024.0−0.410007501000760
17.223625316.24510851.025.1−0.511008001100830
17.9924926618.05012058.826.1−0.811808801180900
Selected sizes from the datasheet — full range available on request. Suitable-span columns A–D follow NESC loading-district conventions.